id: 36754
Назва: Justification of the possibility of building an integrated ultrasonic measuring transducer of natural gas consumption
Автори: Bilynsky Y., Stetsenko А., Ogorodnik K.
Ключові слова: integrated ultrasonic measuring transducer, flow conditioner, straight pipeline section
Дата публікації: 2024-07-29 12:32:22
Останні зміни: 2024-07-29 12:32:22
Рік видання: 2024
Аннотація: The paper establishes the feasibility of constructing an integrated ultrasonic measuring transducer for measuring natural gas consumption. Various schemes for combining ultrasonic transducers with flow conditioning devices, along with several natural gas parameter measuring transducers, were analyzed. The design of an integrated ultrasonic meter that eliminates the need for a standard straight pipeline section and external jet straightener was explored. Simulations of 4-beam ultrasonic meters with known local resistances and the integrated ultrasonic meter were conducted using SolidWorks. The comparative analysis revealed the advantages of the proposed integrated ultrasonic meter.
URI: http://socrates.vsau.org/repository/getfile.php/36754.pdf
Тип виданя: Статті Scopus
Видавництво: Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Srodowiska. 2024. Vol. 14, № 2. P. 47-50. DOI: https://doi.org/10.35784/iapgos.5876
Розташовується в колекціях :
Ким внесений: Адміністратор
Файл : 36754.pdf Розмір : 1328750 байт Формат : Adobe PDF Доступ : Загально доступний
| |
|
|